Youyi YY-D-300-5 Type I 5V 60A 100~240V LED Power Supply
Electrical Specification
Input Electrical Characteristics
Input Voltage Range |
90 Vac ~264Vac |
Rated Input Voltage
|
100 Vac ~240Vac |
Input Frequency Range |
47HZ~63HZ |
Rated Frequency Range |
50HZ~60HZ |
Input Current |
Max. 3.5A at100Vac input and full load
Max. 2.5A at 240Vac input and full load
|
Inrush current |
≤80A at 230Vac
|
Power Factor
|
≥0.95 at 230Vac (Load test)
|
Efficiency |
Efficiency should at 100% load >86.0% at 100Vac
Efficiency should at 100% load >89.0% at 230Vac
|
Output Power |
300W |
Output Channel | CON2(+)(-) |
Rated Output Voltage | +5.0V Vdc |
Voltage accuracy | 2% |
Rated Current | 100Vac to 180Vac/50A
180Vac to 240Vac/60A |
Remark: Test power supply voltage, must measure the power output terminal.
Output Ripple & Noise
Output Channel | Rated Output Voltage |
Output Ripple & Noise |
100Vac to180Vac(50A)180Vac to240Vac(60A) | ||
CON2(+)(-) | +5.0 Vdc |
≤300mV |
Remark:Ripple & Noise
- the Bandwidth of oscilloscope is set to 20MHz.
- On the output side lock 10 cm cable to a 0.1uF ceramic capacitors in parallel and a 10uF electrolytic capacitor to test the ripple and noise.
Turn on Delay Time
Output Channel |
Rated Output Voltage |
Turn on Delay Time |
100Vac to180Vac(50A)
180Vac to240Vac(60A) |
||
CON1(+)(-) |
+5.0Vdc |
≤3S |
Remark: AC voltage to the output voltage on 90% of the time.
Hold up Time
Output Channel |
Rated Output Voltage |
Hold up Time |
100Vac to180Vac(50A)
180Vac to240Vac(60A) |
||
CON1(+)(-) |
+5.0 |
≥5mS |
Remark: Shut down the AC input voltage to the output voltage of 90% of the time.
Output Voltage Rise Time
Output Channel
|
Rated Output Voltage
|
Output Voltage Rise Time |
100Vac to180Vac(50A)
180Vac to240Vac(60A) |
||
CON2(+)(-) |
+5.0 |
≦100mS |
Remark: Output voltage increased from 10% to 90% of the time.
Output Overshoot
Output Channel |
Rated Output Voltage |
Output Overshoot |
100Vac to180Vac(50A)
180Vac to240Vac(60A) |
||
CON2(+)(-) | +5.0 Vdc |
≦10% |
Transient Response
Output Channel |
Rated Output Voltage |
Transient Response |
100Vac to180Vac(50A)
180Vac to240Vac(60A) |
||
CON2(+)(-) |
+5.0 Vdc |
Output:0-50%,50%~100% Slew Rate:1A/uS,
The output overshoot and undershoot should be ≤±10% of Transient Response Recovery Time:200us |
Capacitive Load
The power supply powers up and operates with the 8000uF capacitive loads.
Protection Function
Short Circuit Protection
Item |
Remark |
Short Circuit Protection |
Hiccup, troubleshooting conditions, the power output is restored. |
Over Current Protection
Item |
Over Current |
Remark |
Over Current Protection |
120% ~ 160% |
OCP trigger point must be between 120% and 160%
of rated load current. Power supply output must recover automatically with normal load when the fault condition is removed. |
Input Under Voltage Protection
Item |
Under Voltage |
Remark |
Input Under Voltage Protection | 70Vac to 89Vac | No output power protection(0%-100% LOAD). |
Input Under Voltage Recovery
Item |
Recovery |
Remark |
Input Under Voltage Recovery | 88Vac to 90Vac | Output recovery. (0%-100%LOAD). |
Environmental Condition
Ambient Temperature
Operation Temperature | -10℃ to +70℃(-30°C can start up) |
Storage Temperature | -40℃ to +85℃ |
Relative Humidity
Operating Relative Humidity | 5%RH to 90%RH |
Storage Relative Humidity | 5%RH to 95%RH |
Altitude
Operating Altitude | ≦2000m |
Storage Altitude | ≦2000m |
Climates
Climates | Apply to the tropical climate |
Cooling Method
Cooling Method |
Natural cooling |
Power Derating
The maximum percentage of output load derating from 40°C to 50°C is 1.0%/°C which is 274W at 50°C.
The maximum percentage of output load derating from 50°C to 70°C is 1.67%/°C which is 204W at 70°C.
Reliability
NO. |
Item |
Remark |
5.1 | Power On/off Cycle | Products at room temperature environment, Rated input and
output, switch the 3 s 1000 times the frequency of the cycle. |
5.2 | Burn-In Test | Products in 40℃ environment, input 220Vac, output rated load
operation 72 hours continuously. |
5.3 |
Vibration |
IEC60068-2-6, Sine wave excited, acceleration 10Hz~150Hz at 25M/S2 2.5g peak; 90min per axis for all X, Y, Z direction. IEC60068-2-6, Random: 5Hz–500Hz at 2.09G RMS peak. 20 min per axis for all X,Y,Z direction |
5.4 |
Shock | 49m/s²(5G),11ms, once each X, Y and Z axis |
5.5 | MTBF | The Calculated MTBF should be more than 20,000 hours as per Telcordia SR-332 when AC 220V/50Hz and full load output at |
5.6 | Electrolytic
Capacitor Life |
The Calculated capacitor life shall be more 10 years when AC 220V/50Hz input, 50% load at 35°C ambient. |
Safety
NO. |
Item |
Condition |
Remark |
|
6.1 |
Dielectric Strength |
Primary to Secondary | 3000Vac, 5mA, 60S |
No flying arc and no breakdown |
Primary to Ground | 1500Vac, 5mA, 60S | |||
Secondary to Ground | 500Vac, 5mA, 60S | |||
6.2 | Insulation Resistance | Primary to Secondary | 500Vdc, ≥10MΩ | Under normal atmospheric pressure, relative humidity of 90%, test DC voltage 500V |
Primary to Ground | ||||
Secondary to Ground |
6.3 | Leakage Current | Primary to Secondary | ≤5.0mA | Class I |
6.4 | Ground Impedance | <0.1 ohms. | 32A/2 minutes(UL Certified model: 40A/2 minutes) | |
6.5 | Safety Certification |
/ |
|
EMI
The power supply meets the EN 55022 CISPR 22 Class.
EMC
The power supply meets the following standards: EN61000-3-2: Harmonic Current Emission Class. EN61000-3-3: Voltage fluctuations and Flicker.
IEC 61000-4-2: Electrostatic Discharge, Level 4: ≥ 8KV contact, ≥ 15KV air discharge, Criteria A.
IEC 61000-4-3: Radiated Electromagnetic field, Level 3. Criteria A IEC 61000-4-4: Electrical Fast Transient, Level 3. Criterion A IEC 61000-4-5: Surge; Level 3, Criterion A.
IEC 61000-4-6: Conducted Immunity, Level 3 Criteria A. IEC 61000-4-8: 10A/Meter, Criteria.
IEC 61000-4-11: Voltage dips and interruption.100% dip,1 cycle (20ms), self-recoverable IEC 61000-4-12: Level 3, Criteria A
Derating Curve
Ambient Temperature and Output Current
Input voltage and Output Current
Remark:
- Recommend that the Power Supply should be mounted tightly with the heat sink described.(Heat sink size:250*250*3mm)
- The power supply cannot be used under the environment of more than 264Vac.
Dimensions and Structure
Installation drawing
Plus aluminum plate operation
In order to conform to the ambient temperature and output current drop curve and input voltage and output current drop curve power supply must be installed on an aluminum plate, it is suggested that the size of the aluminum plate is shown in the following figure. To optimize heat dissipation, aluminum surface must be smooth.
To ensure good heat dissipation, at least 5cm of space around the power supply must be reserved during installation, as shown in the figure below
Pin Connection
CN01(Type: 8.25mm,3Pin)
Pin number |
Symbol |
Function |
1 |
L |
AC Input L |
2 |
N |
AC Input N |
3 |
G |
Ground |
CN02(Type: 6*8mm,4Pin)
Pin number |
Symbol |
Function |
4 |
V- |
DC Output - |
5 |
V- |
DC Output - |
6 |
V+ |
DC Output + |
7 |
V+ |
DC Output + |