Youyi YY-D-300-5 Type I 5V 60A 100~240V LED Power Supply

Short Description:

Input voltage:100Vac to 240Vac
Protection function:Short Circuit Protection, Over Load Protection
Operation temperature range:-10℃ to +70℃(-30℃ can start up)
High Efficiency, long life and high reliability
PCB using conformal coating process

 


  • Output Voltage: 5V
  • Output Rated Current: 50A(100Vac to 180Vac);60A(180Vac to 240Vac)
  • Operating temperature: -10℃~70℃
  • Cooling mode: Natural cooling
  • Dimensions: L220 x W48 x H26
  • Weight: 350g
  • Product Detail

    Product Tags

    Electrical Specification

    Input Electrical Characteristics

    Input Voltage Range

    90 Vac ~264Vac
    Rated Input Voltage
    100 Vac ~240Vac

    Input Frequency Range

    47HZ~63HZ

    Rated Frequency Range

    50HZ~60HZ

    Input Current

    Max. 3.5A at100Vac input and full load
    Max. 2.5A at 240Vac input and full load

    Inrush current

    ≤80A at 230Vac

    Power Factor

    ≥0.95 at 230Vac (Load test) 
    Efficiency
    Efficiency should at 100% load >86.0% at 100Vac
    Efficiency should at 100% load >89.0% at 230Vac
    Output Electrical Characteristics

    Output Power 

     300W 
    Output Channel   CON2(+)(-) 
     Rated Output Voltage  +5.0V Vdc 
    Voltage accuracy 2%
    Rated Current 100Vac to 180Vac/50A

    180Vac to 240Vac/60A

    Remark: Test power supply voltage, must measure the power output terminal.

    Output Ripple & Noise

     Output Channel  Rated Output Voltage

    Output Ripple & Noise

    100Vac to180Vac(50A)180Vac to240Vac(60A)
    CON2(+)(-) +5.0 Vdc

    ≤300mV 

    Remark:Ripple & Noise

    • the Bandwidth of oscilloscope is set to 20MHz.
    • On the output side lock 10 cm cable to a 0.1uF ceramic capacitors in parallel and a 10uF electrolytic capacitor to test the ripple and noise. 

    Turn on Delay Time

     

    Output Channel

     

    Rated Output Voltage

    Turn on Delay Time

    100Vac to180Vac(50A)

    180Vac to240Vac(60A)

    CON1(+)(-)

    +5.0Vdc

    ≤3S 

    Remark: AC voltage to the output voltage on 90% of the time.

    Hold up Time

     

    Output Channel

     

    Rated Output Voltage

    Hold up Time

    100Vac to180Vac(50A)

    180Vac to240Vac(60A)

    CON1(+)(-)

    +5.0

    ≥5mS 

    Remark: Shut down the AC input voltage to the output voltage of 90% of the time.

    Output Voltage Rise Time

     

    Output Channel

     

     

    Rated Output Voltage

     

    Output Voltage Rise Time

    100Vac to180Vac(50A)

    180Vac to240Vac(60A)

    CON2(+)(-)

    +5.0

    ≦100mS 

    Remark: Output voltage increased from 10% to 90% of the time.

     

    Output Overshoot

     

    Output Channel

     

    Rated Output Voltage

    Output Overshoot

    100Vac to180Vac(50A)

    180Vac to240Vac(60A)

    CON2(+)(-) +5.0 Vdc

    ≦10% 

     

    Transient Response

     

    Output Channel

     

    Rated Output Voltage

    Transient Response
    100Vac to180Vac(50A)

    180Vac to240Vac(60A)

     

     

     CON2(+)(-)

     

     

     +5.0 Vdc

    Output:0-50%,50%~100% Slew Rate:1A/uS,

    The output overshoot and

    undershoot should be ≤±10% of Transient Response Recovery Time:200us 

     

    Capacitive Load

    The power supply powers up and operates with the 8000uF capacitive loads.

    Protection Function

    Short Circuit Protection

    Item

    Remark

    Short Circuit Protection

    Hiccup, troubleshooting conditions, the power output is restored.

     

    Over Current Protection

    Item

    Over Current

    Remark

     

    Over Current Protection

     

     120% ~ 160% 

    OCP trigger point must be between 120% and 160%

    of rated load current. Power supply output must 

    recover automatically with normal load when

    the fault condition is removed.

     

    Input Under Voltage Protection

    Item

    Under Voltage

    Remark

    Input Under Voltage Protection  70Vac to 89Vac  No output power protection(0%-100% LOAD). 

     

    Input Under Voltage Recovery

    Item

    Recovery

    Remark

    Input Under Voltage Recovery  88Vac to 90Vac Output recovery. (0%-100%LOAD).

    Environmental Condition

    Ambient Temperature

    Operation Temperature -10℃ to +70℃(-30°C can start up)
    Storage Temperature  -40℃ to +85℃ 

     

    Relative Humidity

    Operating Relative Humidity 5%RH to 90%RH
    Storage Relative Humidity  5%RH to 95%RH 

     

    Altitude

    Operating Altitude ≦2000m
    Storage Altitude ≦2000m 

     

    Climates

     Climates Apply to the tropical climate 

     

    Cooling Method

     Cooling Method

    Natural cooling 

     

    Power Derating

    The maximum percentage of output load derating from 40°C to 50°C is 1.0%/°C which is 274W at 50°C.  

    The maximum percentage of output load derating from 50°C to 70°C is 1.67%/°C which is 204W at 70°C.

    Reliability

    NO.

    Item

    Remark

     5.1   Power On/off Cycle Products at room temperature environment, Rated input and

    output, switch the 3 s 1000 times the frequency of the cycle.

     5.2  Burn-In Test Products in 40℃ environment, input 220Vac, output rated load

    operation 72 hours continuously.

     

     5.3

     

    Vibration

    IEC60068-2-6, Sine wave excited, acceleration 10Hz~150Hz at 25M/S2 2.5g peak; 90min per axis for all X, Y, Z direction. IEC60068-2-6, Random: 5Hz–500Hz at 2.09G RMS peak. 20 min per

    axis for all X,Y,Z direction

           5.4

    Shock 49m/s²(5G),11ms, once each X, Y and Z axis  
     5.5 MTBF The Calculated MTBF should be more than 20,000 hours as per Telcordia SR-332 when AC 220V/50Hz and full load output at
     5.6 Electrolytic

    Capacitor Life

    The Calculated capacitor life shall be more 10 years when AC 220V/50Hz input, 50% load at 35°C ambient.  

    Safety

    NO.

    Item

    Condition

    Remark

     

     6.1

     

     Dielectric Strength

    Primary to Secondary  3000Vac, 5mA, 60S  

     No flying arc and no breakdown 

    Primary to Ground  1500Vac, 5mA, 60S
    Secondary to Ground  500Vac, 5mA, 60S
      6.2  Insulation Resistance Primary to Secondary  500Vdc, ≥10MΩ  Under normal atmospheric pressure, relative humidity of 90%, test DC voltage 500V
    Primary to Ground 
    Secondary to Ground
     6.3 Leakage Current Primary to Secondary  ≤5.0mA  Class I
     6.4 Ground Impedance  <0.1 ohms. 32A/2 minutes(UL Certified model: 40A/2 minutes) 
     6.5 Safety Certification

    /

      

    EMI

    The power supply meets the EN 55022 CISPR 22 Class. 

    EMC

    The power supply meets the following standards: EN61000-3-2: Harmonic Current Emission Class. EN61000-3-3: Voltage fluctuations and Flicker.

    IEC 61000-4-2: Electrostatic Discharge, Level 4: ≥ 8KV contact, ≥ 15KV air discharge, Criteria A.

    IEC 61000-4-3: Radiated Electromagnetic field, Level 3. Criteria A IEC 61000-4-4: Electrical Fast Transient, Level 3. Criterion A   IEC 61000-4-5: Surge; Level 3, Criterion A.

    IEC 61000-4-6: Conducted Immunity, Level 3 Criteria A. IEC 61000-4-8: 10A/Meter, Criteria.

    IEC 61000-4-11: Voltage dips and interruption.100% dip,1 cycle (20ms), self-recoverable IEC 61000-4-12: Level 3, Criteria A

    Derating Curve

    Ambient Temperature and Output Current

    1

    Input voltage and Output Current

    2

    Remark:

    • Recommend that the Power Supply should be mounted tightly with the heat sink described.(Heat sink size:250*250*3mm)
    • The power supply cannot be used under the environment of more than 264Vac.

    Dimensions and Structure

     

    Dimensions Dimensions: 220mmx48mmx26mm±0.5mm 

     3

    Installation drawing

    Plus aluminum plate operation

    In order to conform to the ambient temperature and output current drop curve and input voltage and output current drop curve power supply must be installed on an aluminum plate, it is suggested that the size of the aluminum plate is shown in the following figure. To optimize heat dissipation, aluminum surface must be smooth. 

    4

    To ensure good heat dissipation, at least 5cm of space around the power supply must be reserved during installation, as shown in the figure below

    5

    Pin Connection

    CN01(Type: 8.25mm,3Pin) 

    Pin number

    Symbol

    Function

    1

    L

    AC Input L

    2

    N

    AC Input N

    3

    G

    Ground 

     

    CN02(Type: 6*8mm,4Pin) 

    Pin number

    Symbol

    Function

    4

    V-

    DC Output -

    5

    V-

    DC Output -

    6

    V+

    DC Output +

    7

    V+

    DC Output  + 


  • Previous: