Youyi YY-D-300-5 A-Series 5V 60A LED Power Supply
Electrical Specification
Input Electrical Characteristics
Project | YY-D-300-5 |
Normal output power |
300W |
Normal voltage range |
200 Vac ~240Vac |
Input voltage range | 176Vac ~264Vac |
Frequency range |
47HZ~63HZ |
Leakage Current |
≤0.25ma,@220Vac |
Max input AC current |
2A |
Inrush current |
≤60A,@220VAC |
Efficiency(full load) | ≥88% |
Output Electrical Characteristics
Operate temperature rating Curve
Output Voltage And Current Regulation
Project |
YY-D-300-5 |
Output Voltage |
5.0V |
Setting Accuracy (No load) |
±0.05V |
Output Rated Current |
60A |
Peak Current |
65A |
Line Regulation |
±0.5% |
Load Regulation |
Load≤70:±1%(Amount to:±0.05V)V Load>70:±2%(Amount to:±0.1V)V
|
Startup Delay Time
Delay Time |
220Vac Input @ -40~-5℃ |
220Vac Input @ ≥25℃ |
Output Voltage:5.0 Vdc |
≤6S |
≤3S |
- |
- |
- |
Output Dynamic Response
Output Voltage |
Change Rate |
Voltage Range | Load Change |
5.0 Vdc |
1~1.5A/uS |
≤±5% |
@Min.to 50% load and 50% to max load |
- |
- |
- |
DC Output Voltage Rise Time
Output Voltage |
220Vac input & full load |
Note |
5.0 Vdc |
≤50mS |
The rise time is when voltages rise from 10% to 90%. |
DC Output Ripple & Noise
Output Voltage |
Ripple & Noise |
5.0 Vdc |
140mVp-p@25℃ |
240mVp-p@-25℃ |
Measure Methods
A. Ripple & Noise test:Ripple & Noise bandwidth is set to 20mHZ.
B. Use a 0.1uf ceramic capacitor in parallel with a 10uf electrolytic capacitor at output connector terminals for ripple & noise measurements.
Protection Function
Output Short Circuit Protection
Output Voltage |
Comments |
5.0 Vdc |
The power supply will be stopped when the circuit is shorted and restart operating after eliminating malfunction. |
Output Over Load Protection
Output Voltage |
Comments |
5.0 Vdc | The power supply will stop working when the output current is more than 105~138% of rated current and it will restart working after eliminating malfunction. |
Output Voltage |
Comments |
5 Vdc |
The power supply will stop working when the temperature above the set value and it will restart working after solving problem. |
Isolation
Dielectric Strength
Input To Output |
50Hz 3000Vac Ac file test 1 minute,Leakage current≤5mA |
Input To FG |
50Hz 2000Vac Ac file test 1 minute,Leakage current≤5mA |
Output To FG |
50Hz 500Vac Ac file test 1 minute,Leakage current≤5mA |
Insulation Resistance
Input To Output |
DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Output To FG |
DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature) |
Input To FG |
DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Environment Requirement
Environment Temperature
Working Temperature:-10℃~+60℃
Storage Temperature:-40℃ ~ +70℃
Humidity
Working Humidity: Relative humidity is from 15RH to 90RH.
Storage Humidity: Relative humidity is from 15RH to 90RH.
Altitude
Working Altitude: 0 to 3000m
Shock & Vibration
A. Shock: 49m/s2(5G),11ms,once each X,Y and Z axis.
B. Vibration: 10-55Hz,19.6m/s2(2G),20 minutes each along X,Y and Z axis.
Cooling Method
Fan cooling
Specific Cautions
A. The product should be suspended in air or installed on the face of metal when it is assembled, and be avoided to place on the face of non-conducting heat materials such as, plastics, board and so on.
B. The space between each module should be exceeded 5cm in order to avoid affecting cooling of power supply.
MTBF
The MTBF shall be at least 50,000 hours at 25℃ at the condition of full loading.
Pin Connection
The figure below is vertical view of product, Input 5 pin terminal block is on the left side and Output 6 pin terminal block is on the right side.
Table 1 : Input 5 pin terminal block (pitch 9.5mm)
Name |
Function |
L L |
The AC Input Line L |
N N |
The AC Input Line N |
Earth Line |
Table 2 :Output 6 pin terminal block (pitch 9.5mm)
Name |
Function |
V+ V+ V+ |
Output DC positive pole |
V- V- V- |
Output DC negative pole |
Power Supply Mounting Dimension
Dimensions
Outside dimension : L*W*H=215×87×30mm
Method 1. M3 Screws are suitable for 4 tapped holes in the bottom of the shell.
Precautions Of Use
The power supply must work at the condition of insulation and make sure the terminal post of cable is insulation. Besides, make sure the product is grounded well and forbid touching the cabinet to avoid scalding hand.