Youyi YY-D-200-5 110V/220V Type G6 Code Switch 5V 40A LED Power Supply
Electrical Specification
Input Electrical Characteristics
Project |
YY-D-200-5 |
Output Power |
200W |
Input Voltage |
110V Product: 100Vac~135Vac 220V Product: 200Vac~240Vac Switch by toggle the Settings switch inside the product |
Input Voltage Range | 110V Product:100 Vac ~135Vac
220V Product:180 Vac ~264Vac |
Frequency range |
47HZ~63HZ |
Leakage Current |
≤0.25ma, @220Vac |
Maximum Input Current |
2.5A |
Inrush Current |
≤35A, @220Vac |
Efficiency(full load) |
≥85% |
Input 110/220Vac
Output Electrical Characteristics
If customer want the product to work at the environment of - 40℃, please indicate special requirement when customer order it.
Output Voltage And Current Specification
Project |
YY-D-200-5 |
Output Voltage |
5.0V |
Setting Accuracy (No load) |
±0.05V |
Output Rated Current |
40A |
Peak Current |
42A |
Line Regulation |
±0.5% |
Load Regulation |
LOAD≤ 70%:±1%(Amount to:±0.05V)V LOAD> 70%:±2%(Amount to:±0.1V)V |
Startup Delay Time
Delay Time |
220Vac Intput @ -40~-5℃ |
220Vac Intput @ ≥25℃ |
Output Voltage:5.0 Vdc |
≤6S |
≤3S |
- |
- |
- |
Output Dynamic Response
Output Voltage |
Change Rate |
Voltage Range | Load Change |
5.0 Vdc |
1~1.5A/uS |
≤±5% |
@Min.to 50% load and 50% to max load |
- |
- |
- |
Output Voltage Rise Time
Output Voltage |
220Vac input & full load |
Note |
5.0 Vdc | ≤50mS | The rise time is when voltages rise from 10% to 90% . |
Output Ripple & Noise
Output Voltage |
Ripple & Noise |
5.0 Vdc |
140mVp-p@25℃ |
240mVp-p@-25℃ |
Measure Methods
A. Ripple & Noise test:Ripple & Noise bandwidth is set to 20mHZ.
B. Connect a 0.1uf Ceramic Capacitor with a 10uf Electrolytic Capacitor parallel to output terminals to test Ripple & Noise.
Protection Function
Output Short Circuit Protection
Output Voltage |
Comments |
5.0 Vdc |
The power supply will stop working when the short circuit is triggered and it restart working after solving problem. |
Output Over Load Protection
Output Voltage |
Comments |
5.0 Vdc |
The power supply will stop working when the outputcurrent is more than 105~138% of rated current and it will restart working after solving problem. |
Over Temperature Protection
Output Voltage |
Comments |
5.0 Vdc |
The power supply will stop working when the temperature above the set value and it will restart working after solving problem. |
Output Over Voltage Protection
Output Voltage |
Comments |
6.0 Vdc | The output will not exceed 6.0V when external factors trigger malfunction of output. That can avoid the damage to theloader of the power supply. |
Isolation
Dielectric Strength
Input To Output |
50Hz 3000Vac Ac file test 1 minute,Leakage current≤5mA |
Input To FG |
50Hz 2000Vac Ac file test 1 minute,Leakage current≤5mA |
Output To FG |
50Hz 500Vac Ac file test 1 minute,Leakage current≤5mA |
Insulation Resistance
Input To Output |
DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Output To FG |
DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature) |
Input To FG |
DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Environment Requirement
Environment Temperature
Working Temperature:-10℃~+60℃
If customer want the product to work at the environment of - 40℃,please indicate special requirement when customer order it.
Storage Temperature:-40℃ ~ +70℃
Humidity
Working Humidity: Relative humidity is from 15RH to 90RH.
Storage Humidity: Relative humidity is from 15RH to 90RH.
Altitude
Working Altitude: 0 to 3000m
Shock & Vibration
A. Shock: 49m/s2(5G),11ms,once each X,Y and Z axis.
B. Vibration: 10-55Hz,19.6m/s2(2G),20 minutes each along X,Y and Z axis.
Cooling Method
Fan Cooling
Specific Cautions
A. The product should be suspended in air or installed on the face of metal when it is assembled, and be avoided to place on the face of non-conducting heat materials such as, plastics, board and so on.
B. The space between each module should be exceeded 5cm in order to avoid affecting cooling of power supply.
MTBF
The MTBF shall be at least 50,000 hours at 25℃ at he condition of full loading.
Pin Connection
The image below is top view of product and left side is terminal block. The power supply is built-in a switch can be toggled by a screw in order to change the input voltage to 110Vac or 220Vac (The value that shows in switch is the input voltage which have been sett ed).Attention: The power supply will be damage when the input voltage have been setted to 110Vac and the real input voltage is more than 150Vac.
Unit:mm
Table 1 : Input 5 pin terminal block (pitch 9.5mm)
Name |
Function |
L L |
The AC Input Line L |
N N |
The AC Input Line N |
Earth Line |
Table 2 :Output 6 pin terminal block (pitch 9.5mm)
Current through the output terminal block should not exceed 20A, so never overload test and work in that kind of condition. Or the terminal block will be damaged because of high temperature.
Name |
Function |
V+ V+ V+ |
Output DC positive pole |
V- V- V- |
Output DC negative pole |
Power Supply Mounting Dimension
Dimensions
Outside dimension : L*W*H=190×82×30mm