Youyi YY-D-200-5 110V/220V Type G6 Code Switch 5V 40A LED Power Supply

Short Description:

The product is AC-DC constant voltage power supply and it can drive the industrial equipment, like LED display. It have the characteristics of high efficiency, small capacity, a stable output and high reliability. It also have protection function of short circuit protection, over temperature protection and so on.

  • DC Voltage: 5V
  • Output Rated Current: 40A
  • Maximum Input Current: 2.5A
  • Operating temperature: -10℃~60℃
  • Cooling mode: Fan cooling
  • Dimensions: L190 x W82 x H30
  • Weight: 490g
  • Product Detail

    Product Tags

    Electrical Specification

    Input Electrical Characteristics

    Project

     YY-D-200-5

    Output Power

     200W
    Input Voltage

    110V Product: 100Vac~135Vac

    220V Product: 200Vac~240Vac

    Switch by toggle the Settings switch inside the product

    Input Voltage Range 110V Product:100 Vac ~135Vac

    220V Product:180 Vac ~264Vac

    Frequency range

     47HZ~63HZ

    Leakage Current

     ≤0.25ma, @220Vac

    Maximum Input Current

     2.5A

    Inrush Current

     ≤35A, @220Vac

    Efficiency(full load)

     ≥85%

    Input 110/220Vac

    1.1

    Output Electrical Characteristics

    The Derating Curve Of Environment Temperature
    2

    If customer want the product to work at the environment of - 40℃, please indicate special requirement when customer order it.

    Output Voltage And Current Specification

    Project

     YY-D-200-5

    Output Voltage

     5.0V

    Setting Accuracy

    (No load)

     ±0.05V

    Output Rated Current

     40A

    Peak Current

     42A

    Line Regulation

     ±0.5%

    Load Regulation

    LOAD≤ 70%:±1%(Amount to:±0.05V)V

    LOAD> 70%:±2%(Amount to:±0.1V)V

     

    Startup Delay Time

    Delay Time

    220Vac Intput @ -40~-5℃

    220Vac Intput @ ≥25℃

    Output Voltage:5.0 Vdc

    ≤6S

    ≤3S

    -

    -

    -

     

    Output Dynamic Response

    Output Voltage

    Change Rate

    Voltage Range Load Change
    5.0 Vdc

    1~1.5A/uS

    ≤±5%

    @Min.to 50% load and 50% to max load

    -

    -

    -

     

    Output Voltage Rise Time

    Output Voltage

    220Vac input & full load

    Note

     5.0 Vdc   ≤50mS  The rise time is when voltages rise from 10% to 90% .

     

    Output Ripple & Noise

    Output Voltage

    Ripple & Noise

    5.0 Vdc

    140mVp-p@25℃

    240mVp-p@-25℃

    Measure Methods

    A. Ripple & Noise test:Ripple & Noise bandwidth is set to 20mHZ.

    B. Connect a 0.1uf Ceramic Capacitor with a 10uf Electrolytic Capacitor parallel to output terminals to test Ripple & Noise.

    Protection Function

    Output Short Circuit Protection

    Output Voltage

    Comments

     5.0 Vdc

    The power supply will stop working when the short circuit is triggered and it restart working after solving problem.

     

    Output Over Load Protection

    Output Voltage

    Comments

     

     5.0 Vdc

    The power supply will stop working when the outputcurrent is more than 105~138% of rated current and it will restart working after solving problem.

     

    Over Temperature Protection

    Output Voltage

    Comments

     5.0 Vdc

    The power supply will stop working when the temperature above the set value and it will restart working after solving problem.

     

    Output Over Voltage Protection

    Output Voltage

    Comments

      6.0 Vdc The output will not exceed 6.0V when external factors trigger malfunction of output. That can avoid the damage to theloader of the power supply.

    Isolation

    Dielectric Strength

    Input To Output

    50Hz 3000Vac Ac file test 1 minute,Leakage current≤5mA 

    Input To FG

    50Hz 2000Vac Ac file test 1 minute,Leakage current≤5mA 

    Output To FG

    50Hz 500Vac Ac file test 1 minute,Leakage current≤5mA 

     

    Insulation Resistance

    Input To Output

    DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature)

    Output To FG

    DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature)

    Input To FG

    DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature)

    Environment Requirement

    Environment Temperature

    Working Temperature:-10℃~+60℃

    If customer want the product to work at the environment of - 40℃,please indicate special requirement when customer order it.

     

    Storage Temperature:-40℃ ~ +70℃

     

    Humidity

    Working Humidity: Relative humidity is from 15RH to 90RH.

    Storage Humidity: Relative humidity is from 15RH to 90RH.

     

    Altitude

    Working Altitude: 0 to 3000m

    Shock & Vibration

    A. Shock: 49m/s2(5G),11ms,once each X,Y and Z axis.

    B. Vibration: 10-55Hz,19.6m/s2(2G),20 minutes each along X,Y and Z axis.

    Cooling Method

    Fan Cooling

     

    Specific Cautions

    A. The product should be suspended in air or installed on the face of metal when it is assembled, and be avoided to place on the face of non-conducting heat materials such as, plastics, board and so on.

    B. The space between each module should be exceeded 5cm in order to avoid affecting cooling of power supply.

    MTBF

    The MTBF shall be at least 50,000 hours at 25℃ at he condition of full loading.

    Pin Connection

    The image below is top view of product and left side is terminal block. The power supply is built-in a switch can be toggled by a screw in order to change the input voltage to 110Vac or 220Vac (The value that shows in switch is the input voltage which have been sett ed).Attention: The power supply will be damage when the input voltage have been setted to 110Vac and the real input voltage is more than 150Vac.

    3

    Unit:mm

    Table 1 : Input 5 pin terminal block (pitch 9.5mm)

    Name

    Function

    L  L

    The AC Input Line L

    N  N

    The AC Input Line N

     Earth Line

     

    Table 2 :Output 6 pin terminal block (pitch 9.5mm)

    Current through the output terminal block should not exceed 20A, so never overload test and work in that kind of condition. Or the terminal block will be damaged because of high temperature.

    Name

    Function

    V+   V+   V+

    Output DC positive pole

    V-    V-    V-

    Output DC negative pole

    Power Supply Mounting Dimension

    Dimensions

    Outside dimension : L*W*H=190×82×30mm

    4
    Method 1: M3 Screws are suitable for 4 tapped holes in the bottom of the shell.
    The length of screw that is fixed into the power supply must not exceed 3mm.

    Method 2: M3 screws lock in the mounting rack of 3 U grooves under the cabinet.

    Precautions Of Use

    The power supply must work at the condition of insulation and make sure the terminal post of cable is insulation. Besides, make sure the product is grounded well and forbid touching the cabinet to avoid scalding hand.