Wholesales G-energy JPS300V Power Supply with Fan Cooling 110V/220V Input 300W LED Display Switch Power Supply

Short Description:

The power supply has the characteristics of small volume, high efficiency, stable operation and high reliability. The power supply has input under-voltage, output current limiting, output short circuit and so on.


Product Detail

Product Tags

Product Main Specification

Output Power

(W)

Rated Input

Voltage

(Vac)

Rated Output

Voltage (Vdc)

Output Current

Range

(A)

Precision

Ripple and

Noise

(mVp-p)

300

110/220(±20%)

+5.0

0-60.0

±2%

≤150

Environment Condition

Item

Description

Tech Spec

Unit

Remark

1

Working temperature

-30—50

 

2

Storing temperature

-40—80

 

3

Relative humidity

10—90

%

No condensation

4

Heat dissipation method

Fan cooling

 

The power supply   should be installed on the metal plate to dissipate heat

5

Air pressure

80— 106

Kpa

 

6

Height of sea level

2000

m

 

Electrical Character

1

Input character

Item

Description

Tech Spec

Unit

Remark

1.1

Rated voltage range

110/220

Vac

Refer to the

diagram of input

voltage and load

relation.

1.2

Input frequency range

47—63

Hz

 

1.3

Efficiency

≥78.0

%

Vin=220Vac 25℃ Output  Full  Load  (at room temperature)

1.4

Efficiency factor

≥0.45

 

Vin=220Vac

Rated input voltage, output full load

1.5

Max input current

≤5.0

A

 

1.6

Dash current

≤120

A

Cold state test

@220Vac

2

Output character

Item

Description

Tech Spec

Unit

Remark

2.1

Output voltage rating

+5.0

Vdc

 

2.2

Output current range

0-60.0

A

 

2.3

Output voltage adjustable

range

4.9-5.1

Vdc

 

2.4

Output voltage range

±2

%

 

2.5

Load   regulation

±2

%

 

2.6

Voltage stability accuracy

±2

%

 

2.7

Output ripple and noise

≤150

mVp-p

Rated input, output

full load, 20MHz

bandwidth, load side

and 47uf / 104

capacitor

2.8

Start output delay

≤5.0

S

Vin=220Vac @25℃ test

2.9

Output voltage raise time

≤50

ms

Vin=220Vac @25℃ test

2.10

Switch machine overshoot

±5

%

Test

conditions: full load,

CR mode

2.11

Output dynamic

The voltage change is less than±10% VO; the dynamic

response time is less than 250us

mV

LOAD 25%-50%-25%

50%-75%-50%

3

Protection character

Item

Description

Tech Spec

Unit

Remark

3.1

Input under-voltage

protection

/

VAC

Test conditions:

full load

3.2

Input under-voltage

recovery point

/

VAC

 

3.3

Output current limiting

protection point

72-90

A

HI-CUP hiccups

self-recovery, avoid

long-term damage to

power after a

short-circuit power.

3.4

Output short circuit

protection

Self-Recovery

A

 

4

Other character

Item

Description

Tech Spec

unit

Remark

4.1

MTBF

≥40,000

H

 

4.2

Leakage Current

<3.0(Vin=230Vac)

mA

GB8898-2001 test method

Production Compliance Characteristics

Item

Description

Tech Spec

Remark

1

Electric Strength

Input to output

3000Vac/10mA/1min

No arcing, no breakdown

2

Electric Strength

Input to ground

1500Vac/10mA/1min

No arcing, no breakdown

3

Electric Strength

Output to ground

500Vac/10mA/1min

No arcing, no breakdown

Relative Data Curve

Relationship between environmental temperature and load

图片15

Input voltage and load voltage curve

图片16

Load and efficiency curve

图片17

The mechanical character and the definition of connectors( unit:mm)

Dimensions:  length× width× height=217×117×30±0.5.
Assembly Holes Dimensions

图片18

Above is the top view of the bottom shell. The specifications of the screws fixed in the customer system are M3, totaling 4. The length of the fixed screws entering the power supply body should not exceed 3.5mm.

Attention For Application

1、Power supply to be safe insulation, any side of the metal shell with the outside should be more than 8mm safe distance. If less than 8mm need to pad 1mm thickness above PVC sheet to strengthen the insulation.

2、Safe use, to avoid contact with the heat sink, resulting in electric shock.

3、PCB board mounting hole stud diameter not exceeding 8mm.

4、Need a L355mm*W240mm*H3mm aluminum plate as auxiliary heat sink.