Wholesales CZCL A-200AF-5 Slim LED Screen Power Supply Switch Chuanglian 5V 40A 200W
Features
⬤Standard slim model,height 30mm
⬤20~+70C working temperature (refer to derating curve)
⬤Protections: short circuit/overload
⬤100% full load burn-in test
⬤High efficiency, High reliability
⬤2 years warranty
Specification
Model |
A-200AF-2.8X3 | A-200AF-3.3X3 | A-200AF-3.8X3 | A-200AF-4.2X3 | A-200AF-4.5X3 | A-200AF-5X3 | |
Input |
Voltage range |
176~264VAC |
|||||
Input current |
230VAC/2.5A |
||||||
Efficiency |
≥81% |
≥82% |
≥83% |
≥84% |
≥85% |
≥86% |
|
Frequency range |
47~63HZ |
||||||
Leakage current |
<3.5mA/240VAC |
||||||
Inrush current |
60A/230VAC |
||||||
Output |
DC voltage |
2.8V |
3.3V |
3.8V |
4.2V |
4.5V |
5V |
|
Rated current |
40A |
40A |
40A |
40A |
40A |
40A |
|
Power |
112W |
32W |
152W |
160W |
180W |
200W |
|
Voltage adj.range |
/ |
/ |
/ |
/ |
/ |
/ |
|
Ripple and noise |
170mVp-p |
170mVp-p |
170mVp-p |
170mVp-p |
170mVp-p |
170mVp-p |
|
Set up,rise time |
2500ms,50ms/220VAC 100% load |
|||||
|
Hold up time |
10ms/220VAC 100% load |
|||||
|
Line regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load regulation |
± 1.0% |
± 1.0% |
± 1.0% |
± 1.0% |
± 1.0% |
± 1.0% |
|
Output Voltage Accuracy |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
EMC |
EMS |
Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11 |
|||||
|
Harmonic current |
Design refer to:GB17625.1;EN61000-3-2,-3 |
|||||
|
EMC |
Design refer to:EN55022,Class A |
|||||
Safety |
Safety standard |
Design refer to:GB4943/UL1012 |
|||||
Withstand voltage |
I/P-O/P:3KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA each testing time:1min |
||||||
Isolation resistance |
I/P-O/P: 50M ohms; I/P-Case:50M ohms; O/P-Case:50M ohms |
||||||
Protecti on |
Over Voltage |
||||||
|
Over load |
110~165% rated Hiccup mode, recovers automatically after fault condition is removed | |||||
|
Over Temperature |
/ |
|||||
|
Short circuit |
Power supply protection after short circuit, and output can be recovered automatically after eliminating short circuit | |||||
Envirome nt |
Working temperature and humidity |
-20~70℃; 20%~95%RH no condensing (refer to derating curve) | |||||
Storage temperature and humidity |
-30℃~85℃; 10%~95%RH nomondensing | ||||||
Vibration |
Frequency range 10 ~ 500Hz,acceleration 2G, each sweep cycle for 10min, 6 sweep cycles along X, y, Z axis | ||||||
Shock |
Acceleration: 20g, duration: 11ms, 3 impacts along X, y, Z axis | ||||||
Altitude |
2000mtrs (for every 100 m higher than 2000 m, the ambient temperature decreases by 0.6 ℃) | ||||||
Reliability |
MTBF |
25℃:250000Hrs, MIL-217 Method | |||||
Others |
Size |
190*81*30 mm (L*W*H) | |||||
|
Packing |
0.36Kg/piece,30pieces/carton,11KG/carton | |||||
|
Cooling mode |
☑ Free air □ Fan | |||||
|
Extension mode |
three proofings ☑ terminal cover □ Low temperature start (-40℃) others | |||||
Remarks |
*In order to extend the lifetime, it is recommended to configure the load more than 30% of the remainingallowance. For example: the power of the device requires 100W, then use the power of not less than 130W.
*Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. *All electrical performance tests are performed at 25 C. *When the product is used in full load, the aluminum plate with an area of 400 * 400 * 3mm shall be added for auxiliary heat dissipation. *The power supply is a part of the components of the equipment system. All EMC tests are conducted by installing the sample on the metal plate. The power supply shall be confirmed with the terminal equipment for electromagnetic compatibility. |
Derating Curve
Static Characteristics
Mechanical Specification
Product installation and Instructions
-
- 1、When installing, please follow the mechanical size and installation method.
2、Before commissioning, please check and proofread the connections on the terminals to make sure that the input and output, AC and DC, positive and negative poles, voltage and current values are correct, to prevent the
occurrence of reverse connection errors and to avoid damage to power supply and user equipment.
3、Please use the multimeter to measure whether the fire line, zero line and ground line are short-circuited and whether the output terminal is short-circuited before power is turned on.
4、Do not exceed the nominal value of the power supply in use, so as to avoid affecting the reliability of the product. If you need to change the output parameters of the power supply, please consult the technical
department of our company before using the power supply to ensure the effectiveness and reliability of the use.
5、To ensure safety and reduce interference, ensure reliable grounding of grounding end (grounding wire>AWG18#).
6、If the power supply fails, please do not repair it without authorization. Please contact our customer service department as soon as possible.
- 1、When installing, please follow the mechanical size and installation method.