Rong MA300SH5S LED Switch 5V 60A Power Supply

Short Description:

The power supply was designed for LED display,small size, high efficiency, stability, and reliability. Power supply has input undervoltage, output current limiting, output short circuit protection. Power supply will apply with high rectification which greatly improves the power efficiency,can reach 86.0% above, saving energy consumption.


  • DC Voltage: 5V
  • Output Current: 0-60A
  • Operating temperature: -30℃~60℃
  • Cooling mode: Fan forced air cooling
  • Dimensions: L190 x W82 x H30
  • Weight: 490g
  • Product Detail

    Product Tags

    Main Electrical Specification

    Output Power(W) Rated Input Voltage(Vac) Output voltage(Vdc) Output Current(A)

    Regulation accuracy

    Ripple & Noise(mVp-p)

    300

    200—240

    +5V

    0-60

    ±2%

    ≤150

    Environmental conditions

    NO. ITEM Specifications 
    Units Remarks
     

     4.1

     

    Permanent operating temperature

     

     -30-60

     

     ℃

    High temperature aging needs to add heat dissipation plate auxiliary heat dissipation area is not less than 300*200*3mm
     4.2 Storage temperature  -40—80

     
     4.3 Work Relative Humidity  10—50  %  Note 1
     4.4 Storage Relative Humidity  10—90  %  
     4.5 Cooling mode Fan forced air cooling    
     4.6 Atmospheric pressure  80—106 Kpa   
     4.7 Altitude  2000  M   
     4.8 Vibration 10-55Hz 19.6m/S²(2G),20 minutes each along X,Y and Z axis.    
     4.9 Shock 49m/S²(5G),20 once each X,Y and Z axis.    

    Note 1: Please add the new requirement when the power supply will be used for high humidity condition.

     

    Electrical Characteristics

    Input Electrical characteristics

    NO. ITEM

    Specifications 

    Units Remarks
     5.1.1 Rated input voltage  200-240  Vac  Note 2
     5.1.2 Input voltage range  180-264  Vac
     5.1.3 Input frequency range  47—63  Hz  
     5.1.4 Efficiency  ≥86(Vin=220Vac 100%LOAD)  % Full load (room temperature)Note 3
     5.1.5 Maximum input current  ≤4.0  A  
     5.1.6 Inrush current  ≤60  A  

    Note 2:Meanings of rated input voltage and the input voltage range: the rated input voltage is the international general appellation, the highest voltage of rated input voltage float upwards 10%,is the input voltage upper limit, the maximum value, the minimum voltage of rated input voltage float downward 10%, is the input voltage lower limit, the minimum value. Rated input voltage range of 200-240 is corresponding to 180-264. The two terms are not contradictor, essence is consistent, uniform, only two different terms.

    Note 3:Efficiency:Terminal output voltage multiplied by the output current, and then divided by the AC input voltage, divided by the AC input current, divided by the power factor: efficiency=terminal output voltage X output current / (the AC input voltage X AC input current X power factor).

    Output Electrical Characteristics

    NO.

    ITEM

    Specifications 
    Units Remarks
    5.2.1 Output rating voltage

    +5

    Vdc

     
    5.2.2 Output current range

    0—60

    A

     
    5.2.3 Output voltage range

    4.95-5.1

    Vdc

     
     5.2.4 Voltage regulation accuracy  ±1%  VO  
    5.2.5 Load regulation accuracy

    ±1%

    VO

    5.2.6 Regulation accuracy  ±2%  VO
     5.2.7 Ripple and noise  ≤150  mVp-p Full load;20MHz, 104+10uF 静态纹波NOTE 3
    5.2.8 Power output delay  ≤2500  ms  NOTE 4
    5.2.9 Hold up time

    ≥10

    ms

    Vin=220VacNOTE5
    5.2.10 Output voltage rise time  ≤100  ms  NOTE 6
    5.2.11 Off overshoot  ±10%  VO  
    5.2.12

    Output dynamic

    Voltage changes less than ± 5% VO;dynamic response time ≤ 250us   LOAD 25%-50% ,50%-75%

    Note 3: Ripple & noise test: Ripple & noise bandwidth is set to 20MHz, use a 0.10uF ceramic capacitor in parallel with a 10.0uF electrolytic capacitor at output connector for ripple & noise measurements. 

    Note 4: The power delay time measured is when AC power on to 90% of specified output voltage observed on the channel.

    Note 5: The hold-up time measured is when AC power off to 90% of specified output voltage observed on the channel.

    Note 6: The rise time measured is when the output voltage rise from 10% to 90% of specified output Vout observed on the channel wave form.

     

    Protection Features

    NO.

    ITEM

    Specifications

    Units Remarks
     5.3.1 Output current limit protection point  66-90  A  Hiccup Model, Auto-recovery
     5.3.2 Output short circuit protection ≥66  A

    Other Features

    NO.

    ITEM

    Specifications 

    Units Remarks
     5.4.1  MTBF  ≥100,000  H  
     5.4.2 Leakage current  <1.0mA(Vin=220Vac)   GB8898-2001 9.1.1

    Safety Features

    NO.

    ITEM

    Test conditions

    Standard/SPEC
       6.1  Isolation voltage Input-Output  3000Vac/10mA/1min No flashover, nobreakdown
    Input-PE  1500Vac/10mA/1min No flashover, nobreakdown
    Output-PE  500Vac/10mA/1min No flashover, nobreakdown
      6.2  Insulation Resistance Input-Output  DC500V 10MΩ Min
    Input-PE  DC500V 10MΩ Min
    Output-PE  DC500V 10MΩ Min

    Note: Input line (all L&N) should be shorted; and all output should be shorted.

    Derating guidline

    1
    2
    3

    The definition of mechanical properties and connectors(Units:mm)

    Dimensions

    L190 x W82 x H30

     

    Installation hole size

    4

    Pin connection

    Input connection CON1 : 5PIN 9.6mm

    Input connection model: 300V 20A

    NO.

    NO.

    Define.

    1

    PIN1

    LINE

    2

    PIN2

    LINE

    3

    PIN3

    NEUTRAL

    4

    PIN4

    NEUTRAL

    5

    PIN5

    EARTH

    Note: Face the connection from left to right.

     

    Output connection CON2 : 6PIN 9.6mm

    Output connection model: 300V 20A

    NO.

    NO.

    Define.

    1

    PIN1

    GND

    2

    PIN2

    GND

    3

    PIN3

    GND

    4

    PIN4

    +5.0VDC

    5

    PIN5

    +5.0VDC

    6

    PIN6

    +5.0VDC

    Note: Face the connection from left to right.


  • Previous: