G-energy JPS200V5-A Power Supply AC to DC Converter 110V/220V Input for Advertising LED Display Screen
Product Main Specification
Output Power (W) |
Rated Input Voltage (Vac) |
Rated Output Voltage (Vdc) |
Output Current Range (A) |
Precision |
Ripple and Noise (mVp-p) |
200 |
110/200 |
+5.0 |
0-40.0 |
±2% |
≤200 |
Environment Condition
Item |
Description |
Tech Spec |
Unit |
Remark |
1 |
Working temperature |
-30—60 |
℃ |
Please refer to
"temperature
decrement curve" |
2 |
Storing temperature |
-40—85 |
℃ |
|
3 |
Relative humidity |
10—90 |
% |
No condensation |
4 |
Heat dissipation method |
Air cooling |
|
|
5 |
Air pressure |
80— 106 |
Kpa |
|
6 |
Height of sea level |
2000 |
m |
Electrical Character
1 |
Input character | ||||
Item |
Description |
Tech Spec |
Unit |
Remark |
|
1.1 |
Rated voltage |
110/220 |
Vac |
|
|
1.2 |
Input frequency range |
47—63 |
Hz |
|
|
1.3 |
Efficiency |
≥87.0(220VAC) |
% |
Output Full Load (at room temperature) |
|
1.4 |
Efficiency factor |
≥0.5 |
|
Rated input voltage, output full load |
|
1.5 |
Max input current |
≤3.5 |
A |
|
|
1.6 |
Dash current |
≤120 |
A |
Cold state test @220Vac |
|
2 |
Output character | ||||
Item |
Description |
Tech Spec |
Unit |
Remark |
|
2.1 |
Output voltage rating |
+5.0 |
Vdc |
|
|
2.2 |
Output current range |
0-40.0 |
A |
|
|
2.3 |
Output voltage adjustable range |
Unadjustable |
Vdc |
|
|
2.4 |
Output voltage range |
±2 |
% |
|
|
2.5 |
Load regulation |
±2 |
% |
|
|
2.6 |
Voltage stability accuracy |
±2 |
% |
|
|
2.7 |
Output ripple and noise |
≤200 |
mVp-p |
Rated input, output full load, 20MHz bandwidth, load side and 47uf / 104 capacitor |
|
2.8 |
Start output delay |
≤3.5 |
S |
Vin=220Vac @25℃ test |
|
2.9 |
Output voltage raise time |
≤100 |
ms |
Vin=220Vac @25℃ test |
|
2.10 |
Switch machine overshoot |
±5 |
% |
Test conditions: full load, CR mode |
|
2.11 |
Output dynamic |
The voltage change is less than±10% VO; the dynamic response time is less than 250us |
mV |
LOAD 25%-50%-25% 50%-75%-50% |
|
3 |
Protection character | ||||
Item |
Description |
Tech Spec |
Unit |
Remark |
|
3.1 |
Input under-voltage protection |
(75-85)/110 (155-185)/220 |
VAC |
Test conditions: full load |
|
3.2 |
Input under-voltage recovery point |
(75-85)/110 (155-185)/220 |
VAC |
||
3.3 |
Output current limiting protection point |
48-65 |
A |
|
|
3.4 |
Output short circuit protection |
Self-Recovery |
A |
HI-CUP hiccups self-recovery, avoid long-term damage to power after a
short-circuit power. |
|
3.5 |
Over voltage protection |
/ |
V |
||
4 |
Other character | ||||
Item |
Description |
Tech Spec |
unit |
Remark |
|
4.1 |
MTBF |
≥40,000 |
H |
|
|
4.2 |
Leakage Current |
<10(Vin=230Vac) |
mA |
GB8898-2001 test method |
Production Compliance Characteristics
Item |
Description |
Tech Spec |
Remark |
|
1 |
Electric Strength |
Input to output |
3000Vac/10mA/1min |
No arcing, no breakdown |
2 |
Electric Strength |
Input to ground |
1500Vac/10mA/1min |
No arcing, no breakdown |
3 |
Electric Strength |
Output to ground |
500Vac/10mA/1min |
No arcing, no breakdown |
Relative Data Curve
Relationship between environmental temperature and load
Input voltage and load voltage curve
Load and efficiency curve
The mechanical character and the definition of connectors( unit:mm)
Dimensions: length× width× height=190×82×30±0.5.
Assembly Holes Dimensions
Attention For Application
1、Safe use, to avoid contact with the heat sink, resulting in electric shock.
2、High-voltage electricity inside,please don`t open unless professionals
3、Must be installed vertically,inversely or horizontally are not allowed
4、Keep objects 10 cm away for convection