Product Main Specification
Output Power
(W) |
Rated Input Voltage
(Vac) |
Rated Output Voltage(Vdc) | Output Current
Range(A) |
Precision | Ripple and
Noise (mVp-p) |
300 |
180—264 |
5.0 |
0-60 |
±2% |
≤200mVp-p @25℃ @-30℃(Test After working at full load for half an hour) |
Environment Condition
Item |
Description |
Tech Spec |
Unit |
Remark |
1 | Working temperature | -30—50 | ℃ | Refer to the use ofenvironmental
temperature and load curve. |
2 | Storing temperature | -40—85 | ℃ | |
3 | Relative humidity | 10—90 | % | |
4 | Heat dissipation method | Natural cooling | The power supplyshould be installed
on the metal plate to dissipate heat |
|
5 | Air pressure | 80— 106 | Kpa |
Electrical Character
1 | Input character | |||
Item | Description | Tech Spec | Unit | Remark |
1.1 | Normal voltage range | 200-240 | Vac |
Refer to the diagram of input voltage and load relation. |
1.2 | Input frequency range | 50—60 | Hz |
|
1.3 |
Efficiency |
≥85 | % |
Vin=220Vac 25℃ Output Full Load ( at room temperature) |
1.4 |
Efficiency factor |
≥0.5 |
Vin=220Vac Ratedinput voltage, output full load |
1.5 | Max input current | ≤3.5 | A | |
1.6 | Dash current | ≤120 | A | Cold state test@220Vac |
2 | Output character | |||
Item | Description | Tech Spec | Unit | Remark |
2.1 | Output voltage rating | 5.0 | Vdc | |
2.2 | Output current range | 0-60 | A | |
2.3 | Output voltage adjustablerange | / | Vdc | |
2.4 | Output voltage range | ±2 | % | |
2.5 | Load regulation | ±2 | % | |
2.6 | Voltage stability accuracy | ±2 | % | |
2.7 |
Output ripple and noise |
≤200 |
mVp-p |
Rated input, output full load, 20MHz bandwidth, load side and 47uf / 104 capacitor |
2.8 | Start output delay | ≤3.0 | S | Vin=220Vac @25℃ test |
2.9 | Output voltage raise time | ≤100 | ms | Vin=220Vac @25℃ test |
2.10 | Switch machine overshoot | ±10 | % |
Conditions: full load, CR mode test |
2.11 |
Output dynamic |
The voltage change is less than
±10% VO ; the dynamic response time is less than 250us |
mV |
LOAD 25%-50%-25% 50%-75%-50% |
|
3 | Protection character | ||||
Item |
Description |
Tech Spec |
Unit |
Remark |
|
3.1 |
Input under-voltage protection |
140-175 | VAC |
Test conditions : full load |
|
3.2 |
Input under-voltage recovery point |
145-175 | VAC | ||
3.3 |
Output current limiting protection point |
72-90 | A | HI-CUP hiccups
self-recovery, avoid long-term damage to power after a short-circuit power. |
|
3.4 |
Output short circuit protection |
When the output short
circuit is relieved, the power supply can be restored to normal. |
/ |
||
Note: |
|||||
4 | Other character | ||||
Item |
Description |
Tech Spec |
unit |
Remark |
|
4.1 | MTBF | ≥40,000 | H | ||
4.2 |
Leakage Current |
≤3.5(Vin=230Vac) | mA | GB8898-2001 test method |
Production Compliance Characteristics
Item |
Description |
Tech Spec |
Remark |
|
1 |
Electric Strength |
Input to output |
3000Vac/10mA/1min |
No arcing, no breakdown |
2 |
Electric Strength |
Input to ground |
1500Vac/10mA/1min |
No arcing, no breakdown |
3 |
Electric Strength |
Output to ground |
500Vac/10mA/1min |
No arcing, no breakdown |
Relative Data Curve
The mechanical character and the definition of connectors( unit:mm)
Dimensions: length× width× height=190×82×30±0.5mm
Assembly Holes Dimensions
Attention For Application
1、Power supply to be safe insulation, any side of the metal shell with the outside should be more than 8mm safe distance. If less than 8mm need to pad 1mm thickness above PVC sheet to strengthen the insulation
2、Safe use, to avoid contact with the heat sink, resulting in electric shock.
3、PCB board mounting hole stud diameter not exceeding 8mm.
4、Need a L355mm*W240mm*H3mm aluminum plate as auxiliary heat sink.